Products >> Detectors >> SELDI
SELDI

SCINTI-ELECTRONIC Detectors

Single and multichannel
Module concept
CWO & CsI(Tl) based SELDI
Radiation sensitivity:  30 (CWO), 90 (CsI(Tl)) nA·min·R-1·cm-2
11 modifications


NEW DESIGN: High sensitive spectrometric SELDI detector on the base on new light collection system and module concept.

Seldi is a series of scinti-electronic radiation detectors on the basis of "scintillator - photodiode" assembly.

At present a concept of a module-type detection block has been developed. Such block is mounted of individual modules with a specified energy resolution. Each module is designed so that to provide a maximum light yield and energy resolution. The number of modules is defined proceeding from the required sensitivity of the block as a whole. The block is positioned in a common housing with a common scheme of signal processing from all the modules.

The module-type block allows to determine the direction to the radiation source while not displacing the block. The ratio "signal-noise" has been improved.

The base detection blocks with the crystal volume from 8 to 64 and energy resolution by 137Cs from 5.5 to 14% have been developed.

The consumption power for one module - 60 mWt.

.Back to top

.Back to top

SELDI Module Detectors

ParameterSELDI-1SELDI-2
Energy range, MeV91
Sensitivity, pulse/s/mkR/h on 137Cs>11>4.5
Sensitivity, pulse/s/mkR/h on on 60Cs>9>3.0
Sensitivity, pulse/s/mkR/h on 241Am>6>1.5
Energy resolution on 137Cs, %7.5-8.57.5
The ratio peak/valley by 60Co not less than1010
Output pulse parameters - pulse height, mV/keV0.80.8
Output pulse parameters - duration on 0.5 pulse height, mks12.550
In-set temperature sensor, mV/°C22
Supply voltage, V±9±9
Consumed current, mA1415
Crystal size, mm44x44x5222x22x52
Detector size, mmdia.64x112dia.35x100

.Back to top

SELDI Type Detectors

Type & Nomencla tureDimensions [mm]Radi ation sensi vity, nAminR -1cm-2Energy range, meVInput window area [mm]Channels number, stepOverall dimension [mm]Intended appli cations
SELDI-M.01 SELDI-M.02CdWO4, CsI(Tl) 16x(4x4x1.4)30, 900.03-0.5 (X-rays)4x1.416(1.57)25.4x20x15Inspection control
SELDI.126-01 SELDI.126-02CdWO4 2x(20x1.4x4) 2x(20x1.4x8)300.15-10 (gamma)4x1.4 8x1.42(1.7)5x8x35Tomography
SELDI.127A SELDI.127BCdWO4, CsI(Tl) 16x(4x12x1.4)30, 900.03-0.2 (X-rays)2x1.416(1.57)25.4x26x10Defecto scopy
SELDI.128-01CsI(Tl) 10x10x1010-50.05-310x10119.5x29.5x20Dosimetry
SELDI.129CdWO4 10x10x10300.01-10 (gamma)10x10 dia.111dia.23x25Dosimetry
SELDI-M.03CsI(Tl) 16x(4x4x1.4)90±10%0.03-0.2 (X-rays)4x1.516(1.57)25.4x20x15Inspection control
SELDI-M.05CsI(Tl) 32x(4x4x0.7)900.03-0.5 (X-rays)4x0.732(0.78)25.4x35x15Introscopy
SELDI-M.08CsI(Tl) 32x(4x4x0.7)90±10%0.05-3(X-rays)9x10117x17x11Introscopy
SELDI.131A02CsI(Tl) 32x(4x4x0.7)90±10%0.01-0.05(X-rays)4x1.216(1.6)25.4x20x5Introscopy

.Back to top